Overview of Conformity to EN50131 Standard
This section gives an overview of the SPC compliance to the EN50131 standard.
Address of Certifying Body |
---|
VdS (VdS A/C/EN/SES Approval) |
SPC products listed have been tested according to EN50131-3:2009 and all relevant RTC specifications.
Product Type |
Standard |
---|---|
|
EN50131 Grade 3 |
|
EN50131 Grade 2 |
Specific information in relation to EN50131 requirements can be found in the following sections in this document.
Note: Compliance with Section 4.2.2 of EN 50131-5-3
Upon entering Engineer Walktest, the signals between the transmitter and the detectors are attenuated by 8dB. This provides immunity to attenuation as required by EN 50131-5-3.
EN50131 Requirement (and relevant section) |
Relevant Vanderbilt documentation |
---|---|
Operating temperature and humidity range |
Technical data: |
Weights and dimensions |
Technical data: |
Fixing details |
|
Installation, commissioning and maintenance instructions, including terminal identifications |
|
Type of interconnections (see 8.8) |
Technical data: |
Details of methods of setting and unsetting possible (see 11.7.1 to 11.7.3 and Tables 23 to 26) |
User programming via the keypad: |
Serviceable parts |
Technical data: |
Power supply requirement if no integrated PS |
See installation instructions for SPCP33x and SPCP43x Expander PSUs. |
Where PS is integrated, the information required by EN 50131-6:2008, Clause 6 |
Technical data: |
Maximum number of each type of ACE and expansion device. |
Technical data: |
Current consumption of the CIE and each type of ACE and expansion device, with and without an alarm condition. |
See relevant installation instructions. |
Maximum current rating of each electrical output |
Technical data: |
Programmable functions provided |
|
How indications are made inaccessible to level 1 users when level 2, 3 or 4 user is no longer accessing the information (see 8.5.1) |
|
Masking/reduction of range signals/messages processed as “fault” or “masking” events (see 8.4.1, 8.5.1 and Table 11) |
PIR masking is always reported as a zone masked event (SIA - ZM). Additionally, anti-mask can cause an alarm, tamper, trouble or no additional action depending on configuration Current defaults of PIR addition effect: Ireland
UK, Europe, Sweden, Swiss, Belgium
|
Prioritization of signal and message processing and indications (see 8.4.1.2, 8.5.3) |
Using the LCD keypad interface Using the Comfort keypad interface - see About the Comfort keypad |
Minimum number of variations of PIN codes, logical keys, biometric keys and/or mechanical keys for each user (see 8.3) |
|
Method of time-limiting internal WD for level 3 access without level 2 authorization (see 8.3.1) |
Not supported - Engineer cannot access system without permission. |
Number and details of disallowed PIN codes (see 8.3.2.2.1) |
|
Details of any biometric authorization methods used (see 8.3.2.2.3) |
Not applicable |
Method used to determine the number of combinations of PIN codes, logical keys, biometric keys and/or mechanical keys (see 11.6) |
|
Number of invalid code entries before user interface is disabled (see 8.3.2.4) |
|
Details of means for temporary authorization for user access (see 8.3.2) |
User Menus – Grant Access |
If automatic setting at pre-determined times provided, details of pre-setting indication and any automatic over-ride of prevention of set (see 8.3.3, 8.3.3.1) |
|
Details of conditions provided for the set state (see 8.3.3.4) |
|
Notification of output signals or messages provided (see 8.6) |
|
Other output configurations to interface with I&HAS components (see 8.2) |
|
Criteria for automatic removal of “soak test” attribute (see 8.3.9) |
|
Number of events resulting in automatic inhibit |
|
If ACE is Type A or Type B (see 8.7) and whether portable or moveable (see 11.14) |
All devices are hardwired and powered by system PSUs. See the relevant technical data on PSUs (separate documents). |
Component data for non-volatile memory components (see Table 30, step 6) |
See user documentation for SPCK420/421 and SPCK620/623 keypads. |
Life of memory support battery (see 8.10.1) |
N/A. Stored in non-volatile memory. |
Optional functions provided (see 4.1) |
|
Additional functions provided (see 4.2, 8.1.8) |
|
Access levels required to access such additional functions provided |
User configuration (browser) - see Adding/Editing a User |
Details of any programmable facility that would render an I&HAS non-compliant with EN 50131-1:2006, 8.3.13 or compliant at a lower security grade, with instruction on consequent removal of compliance labeling (see 4.2 and 8.3.10). |
SPC products listed have been tested according to EN50131-6, and all relevant RTC specifications.
Product Type |
Standard |
---|---|
|
EN50131-6 |
|
EN50131-6 |