Edit Keypads

To edit keypads:

  1. Scroll to KEYPADS > EDIT.

  2. Press SELECT.

  3. Scroll to the device to be edited and press SELECT.

    The configuration settings for a standard keypad and comfort keypad are described in the sections below.

  4. Press BACK to exit the menu.

LCD Keypad Settings

Configure the following settings for the keypad.

Setting

Description

Description

Enter a unique description to identify the keypad.

Function Keys (in idle state)

Panic

Select Enable, Disable or Enabled Silent. If enabled, panic alarm is activated by pressing the 2 soft keys together.

Verification

If you assign a verification zone to the keypad, when a panic alarm is triggered by pressing 2 soft keys together or by entering a duress code, audio and video events are activated.

Visual Indications

Backlight

Select when keypad backlight is on. Options are: On after key is pressed; Always on; Always off.

Indicators

Enable or disable the LED’s on the keypad.

Setting state

Select if setting state should be indicated in idle mode.

Audible Indications

Buzzer

Enable or disable the buzzer on the keypad.

Partset Buzzer

Enable or disable buzzer during exit time on Partset.

Keypress

Select if the speaker volume for the key presses should be activated.

Deactivation

Calendar

Select if the keypad should be limited by calendar. See Calendars.

Mapping gate

Select if keypad should be limited by a mapping gate.

Keyswitch

Select if keypad should be limited by a keyswitch.

PACE Entry

Tick this box to disable the keys on the keypad during the entry time when a PACE is configured on the keypad.

Areas

Location

Select the secured area where the keypad is located.

Areas

Select which areas can be controlled through keypad.

Options

Delay Fullset

Select to configure a delayed set across all keypads. The location of the keypad is ignored and all areas will perform a full exit time count down.

 

 

NOTICE: An area should be assigned to a keypad only if the keypad is inside the assigned area, and if an entry/exit route is defined. If an area is assigned, when the particular area is set or unset then entry and exit timers are used (if configured). Other features related to entry/exit routes also become available. If no area is assigned, the area is set or unset immediately and other entry/exit features are not available.

Comfort Keypad Settings

Configure the following settings for the comfort keypad.

Setting

Description

Description

Enter a unique description to identify the keypad.

Function Keys (in idle state)

Panic

Select Enable, Disable or Enabled Silent. If enabled, panic alarm is activated by pressing F1 and F2 soft keys together.

Fire

Enable to allow fire alarm to be activated by pressing F2 and F3 soft keys together.

Medical

Enable to allow medical alarm to be activated by pressing F3 and F4 soft keys together.

Fullset

Enable to allow Fullset to be activated by pressing F2 key twice.

Partset A

Enable to allow Partset A to be activated by pressing F3 key twice.

Partset B

Enable to allow Partset B to be activated by pressing F4 key twice.

Verification

If you assign a verification zone to the comfort keypad, when a Medical, Panic or Fire event is triggered, or if a user enters a duress code, then audio and video events are activated.

Visual indications

Backlight

Select when keypad backlight is on. Options are: On after key is pressed; Always on; Always off.

Backlight Level

Select the intensity of illumination of the backlight. Range 1–8 (High).

Indicators

Enable or disable the LED’s on the keypad.

Setting state

Enable if setting state should be indicated in idle mode. (LED)

Logo

Enable if logo should be visible in idle mode.

Analog Clock

Select position of clock if visible in idle mode. Options are Left Aligned, Center Aligned, Right Aligned or Disabled.

Emergency

Enable if Panic, Fire and Medical function keys should be indicated in the LCD display.

Direct Set

Enable if Fullset/Partset function keys should be indicated in the LCD display.

Audible indications

Alarms

Select speaker volume for alarm indications or disable sound.

Entry/Exit

Range is 0–7 (max volume).

Chime

Select speaker volume for entry and exit indications or disable sound.

Keypress

Range is 0–7 (max volume).

Voice Annunciation

Select speaker volume for chime or disable sound.

Partset Buzzer

Range is 0–7 (max volume).

Deactivation

Calendar

Select if the keypad should be limited by calendar.

Mapping gate

Select if keypad should be limited by a mapping gate.

Keyswitch

Select if keypad should be limited by a keyswitch.

PACE Entry

Tick this box to disable the keys on the keypad during the entry time when a PACE is configured on the keypad.

Areas

Location

Select the secured area where the keypad is located.

Areas

Select which areas can be controlled through keypad.

Options

Delay Fullset

Select to configure a delayed set across all keypads. The location of the keypad is ignored and all areas will perform a full exit time count down.

 

 

NOTICE: An area should be assigned to a keypad only if the keypad is inside the assigned area, and if an entry/exit route is defined. If an area is assigned, when the particular area is set or unset then entry and exit timers are used (if configured). Other features related to entry/exit routes also become available. If no area is assigned, the area is set or unset immediately and other entry/exit features are not available.