Wireless
Wireless sensor support on the SPC panel is provided by wireless modules (868MHz). There are two types of wireless modules: one-way SiWay RF Kit (SPCW110, 111, 112, 114 ) and two-way SPCW120 Wireless Transceiver. The SiWay RF Kit is fitted in the controller, on the keypad, or by installing a wireless expander. The SPC two-way wireless module is fitted into modem slot 2 of the control panel. See the table below for information on which devices can be enrolled with each type of transceiver.
For CE regulatory compliance, the SPCW120 product can only be fitted to the following products:
|
Devices compatible with a one-way transceiver
Wireless sensors |
ADM-I12W1 |
Wireless Fresnel PIR detector, 12m wide angle |
IR160W6-10 |
Wireless PIR detector with black triplex mirror, 18m wide angle, 868MHz |
|
IMKW6-10 |
Wireless magnet contact, 868MHz |
|
IMKW6-10B |
Wireless magnet contact, 868MHz (brown) |
|
OPZ-W1-RFM6 |
SiWay radio module (plug-in to smoke alarm) |
|
IRCW6-11 |
Remote control FOB with 4 button control |
|
IPAW6-10 |
Personal transmitter |
|
WPA |
Wireless personal alarm |
Devices compatible with a two-way transceiver
Sensors |
WPIR |
Wireless 12m PIR detector with pet immunity option |
WPIR-CRT |
Wireless curtain PIR detector |
|
WMAG |
Wireless magnetic contact (slim) |
|
WMAG-I |
Magnetic contact with additional input |
|
WSMK | Wireless smoke detector | |
Outputs | WSIR-INT | Wireless indoor sounder |
WSIR-EXT | Wireless outdoor sounder | |
Repeaters | WRPTR | Wireless signal repeater plug |
WRMT |
Remote control FOB with 4 button control |
|
WPAN |
Wireless personal alarm button |
For instructional videos on wireless devices and transceivers please go to http://van.fyi?Link=Wireless_devices |
Select a wireless programming option
To select a wireless programming option:
-
Scroll to WIRELESS and press OK.
-
Scroll to the desired programming option. Options are described in the following table:
SENSORS |
It may be necessary to change the type of sensor enrolled on the system if the sensor type was incorrectly identified in the enrolment process. The following options are available for sensors:
|
|
OUTPUTS |
|
|
REPEATERS |
|
|
WPA1 |
Add, edit or remove a WPA (Wireless Personal Alarm).
|
|
SETTINGS | ||
2 WAY WIRELESS |
Enable or disable two-way wireless depending on the transceiver you are using. Enable two-way wireless if you are using SPCW120 Wireless Transceiver. Disable two-way wireless if you are using aSiWay RF Kit (SPCW110, 111, 112, 114 ) and not using a SPCW120 Wireless Transceiver. |
|
FILTER LOW SIGNL |
Enableto configure the panel to disregard low strength signals (RF strengths 0 and 1). |
|
DETECT RF JAM |
Enable to activate an alert on detection of RF interference. |
|
WIRELESS LOST |
Enable to send a Wireless Lost event over CID/SIA and FLexC on loss of wireless signal. |
|
SUPERVISION TIME | Browser option is Supervision ("Two way Wireless Supervision time in minutes") | |
EXTERNAL ANTENNA |
Enable an external antenna. |
|
SUPERVISION |
Enable tamper supervision. Browser option is Missing Supervision ("Select whether missing supervision for a sensor will raise a zone tamper") |
|
RF FOB SOS |
Disable the RF FOB SOS or specify the panel action from the following options: PANIC, PANIC SILENT, USER MEDIC, USER HOLDUP, RF OUTPUT. |
|
WPA TEST SCHED. |
Enter a maximum period (in days) between WPA tests. Max is 365 days, 0 days means that the WPA test disabled. |
|
PREVENT SET TIME |
Enter a time in minutes after which, if the sensor or WPA fails to report, setting is prevented for the area where the wireless zone is. Max is 720 minutes, 0 minutes means that checking is disabled. |
|
DEVICE LOST TIME |
Enter the number of minutes after which the wireless device is reported as lost if it fails to report within this time frame. (Min is 20 and max is 720 minutes. 0 means that checking is disabled.) |
1A WPA is compatible with SiWay RF Kit (SPCW110, 111, 112, 114 ) only.