Edit

Prerequisites

  • A modem is installed and identified by the system.

  • The function SMS Authentication is activated in OPTIONS (see Options).

  1. Scroll to SMS > EDIT and press SELECT.

  2. Select an engineer or user SMS ID to edit.

SMS NUMBER

Enter the number to which the SMS will be sent (requires three-digit country code prefix).

Note: Engineer SMS number can deleted by resetting it 0. User SMS numbers cannot be deleted.

EDIT USER

Select a new user for this SMS ID if required.

EVENT FITLTER

Select the panel events which the user or engineer will receive via SMS. Select ENABLED or DISABLED. Events that are enabled are indicated with an asterisk * before the event in the list.

CONTROL RIGHTS

Select the operations that the user or engineer can perform remotely on the panel through SMS. See SMS Commands

 

 

NOTICE: HOLDUP alarm events are not transmitted via SMS.

 

 

If the phone line is connected to the PSTN network via a PBX, the appropriate line access digit should be inserted before the called party number. Ensure that Calling Line Identity (CLI) is enabled on the line selected to make the call to the SMS network. Consult the PBX administrator for details.