Options
-
Scroll to OPTIONS and press SELECT.
-
Scroll to the desired programming option:
The programming options displayed in the OPTIONS menu vary depending on the security grade of the system (see right column).
WARNING: To change the region on your panel, it is strongly recommended that you default your panel and select a new region as part of the start up wizard. |
Variable |
Description |
Default |
---|---|---|
SECURITY GRADE |
Determines the Security Grade of the SPC Installation.
|
Grade: 2 Country: n/a |
REGION |
Determines the specific regional requirements that the installation complies with. Options are UK, IRELAND, EUROPE, SWEDEN, SWITZERLAND, BELGIUM, GERMANY and FRANCE |
|
APPLICATION |
Determines whether SPC is being installed for use in a commercial business or a private residence. Choose between COMMERCIAL (see Commercial mode operation), DOMESTIC (see Domestic mode operation) or FINANCIAL. |
Domestic |
See Options for more details of the following OPTIONS.
PARTSET A |
RENAME TIMED ACCESS to E/EXIT E/EXIT to ALARM LOCAL |
PARTSET B
|
RENAME TIMED ACCESS to E/EXIT E/EXIT to ALARM LOCAL |
CALL ARC MESSAGE |
DISPLAY MESSAGE (ENABLED/DISABLED) |
CONFIRMATION |
VDS DD243: GARDA EN50131-9 |
CONFIRM ZONES |
Select NO. OF ZONES. |
AUTO RESTORE |
ENABLED/DISABLED |
KEYFOB RESTORE |
ENABLED/DISABLED |
USER DURESS |
DISABLED PIN +1 PIN +2 |
RETRIGGER BELL |
ENABLED/DISABLED |
BELL ON 1ST |
ENABLED/DISABLED |
BELL ON FTS |
ENABLED/DISABLED |
STROBE ON FTS |
ENABLED/DISABLED |
ALARM ON EXIT |
ENABLED/DISABLED Only available in ENGINEER CONFIG mode as setting is not in accordance with EN50131. |
LANGUAGE |
SYSTEM LANGUAGE IDLE STATE :LANGUAGE |
PIN DIGITS |
4 DIGITS 5 DIGITS 6 DIGITS 7 DIGITS 8 DIGITS |
CODED RESTORE |
ENABLED/DISABLED |
WEB ACCESS |
ENABLED/DISABLED Allows/restricts access to the web browser. |
OPEN ZONES |
ENABLED/DISABLED |
ALLOW ENGINEER |
ENABLED/DISABLED |
ALLOW MANUFACT. * |
ENABLED/DISABLED |
SHOW STATE |
ENABLED/DISABLED |
EOL RESISTANCE |
NONE |
SMS AUTH MODE |
PIN ONLY CALLER ID ONLY PIN + CALLER ID SMS PIN ONLY SMS PIN + CALLER ID |
PACE AND PIN |
ENABLED/DISABLED |
RESTORE ON UNSET |
ENABLED/DISABLED Note: To comply with PD6662, you must disable this option. |
ENGINEER RESTORE |
ENABLED/DISABLED |
OFFLINE TAMPER |
ENABLED/DISABLED |
ENGINEER LOCK |
ENABLED/DISABLED If enabled, system cannot be reset using yellow button on controller unless an Engineer PIN is input on the keypad. |
SECURE PIN |
ENABLED/DISABLED |
CLOCK SETTINGS |
AUTOMATIC DST MAINS TIME SYNC |
SUSPICION AUDIBLE |
ENABLED/DISABLED |
SHOW CAMERAS |
ENABLED/DISABLED |
SEIS TEST ON SET |
ENABLED/DISABLED |
ALERT FORBID SET |
ENABLED/DISABLED |
ANTIMASK SET |
DISABLED TAMPER FAULT ALARM |
ANTIMASK UNSET |
DISABLED TAMPER FAULT ALARM |
RETRIGGER DURESS |
ENABLED/DISABLED |
RETRIGGER PANIC |
ENABLED/DISABLED |
SILENCE AUD VER. |
ENABLED/DISABLED |
ENGINEER EXIT |
ENABLED/DISABLED |
* Not available for SPC42xx, SPC43xx.