Options

  1. Scroll to OPTIONS and press SELECT.

  2. Scroll to the desired programming option:

    The programming options displayed in the OPTIONS menu vary depending on the security grade of the system (see right column).

 

WARNING: To change the region on your panel, it is strongly recommended that you default your panel and select a new region as part of the start up wizard.

 

Variable

Description

Default

SECURITY GRADE

Determines the Security Grade of the SPC Installation.

  • Irish and European Regions:
    –EN50131 Grade 2
    –EN50131 Grade 3
    –Unrestricted

  • UK Region:
    –PD6662 (EN50131 Grade 2 based)
    –PD6662 (EN50131 Grade 3 based)
    –Unrestricted

  • Swedish Region:
    –SSF1014:3 Larmclass 1
    –SSF1014:3 Larmclass 2
    –Unrestricted

  • Belgium Region:
    –TO-14 (EN50131 Grade 2 based)
    –TO-14 (EN50131 Grade 3 based)
    –Unrestricted

  • Switzerland Region:
    –SWISSI Cat 1
    –SWISSI Cat 2
    –Unrestricted

  • Spanish Region
    –EN50131 Grade 2
    –EN50131 Grade 3

  • German Region
    –VdS Class A
    –VdS Class C
    –Unrestricted

  • France
    –NFtyp2
    –NFtyp3
    –Unrestricted

Grade: 2

Country: n/a

REGION

Determines the specific regional requirements that the installation complies with. Options are UK, IRELAND, EUROPE, SWEDEN, SWITZERLAND, BELGIUM, GERMANY and FRANCE

 

APPLICATION

Determines whether SPC is being installed for use in a commercial business or a private residence. Choose between COMMERCIAL (see Commercial mode operation), DOMESTIC (see Domestic mode operation) or FINANCIAL.

Domestic

See Options for more details of the following OPTIONS.

PARTSET A

RENAME

TIMED

ACCESS to E/EXIT

E/EXIT to ALARM

LOCAL

PARTSET B

 

RENAME

TIMED

ACCESS to E/EXIT

E/EXIT to ALARM

LOCAL

CALL ARC MESSAGE

DISPLAY MESSAGE (ENABLED/DISABLED)

CONFIRMATION

VDS

DD243:

GARDA

EN50131-9

CONFIRM ZONES

Select NO. OF ZONES.

AUTO RESTORE

ENABLED/DISABLED

KEYFOB RESTORE

ENABLED/DISABLED

USER DURESS

DISABLED

PIN +1

PIN +2

RETRIGGER BELL

ENABLED/DISABLED

BELL ON 1ST

ENABLED/DISABLED

BELL ON FTS

ENABLED/DISABLED

STROBE ON FTS

ENABLED/DISABLED

ALARM ON EXIT

ENABLED/DISABLED

Only available in ENGINEER CONFIG mode as setting is not in accordance with EN50131.

LANGUAGE

SYSTEM LANGUAGE

IDLE STATE :LANGUAGE

PIN DIGITS

4 DIGITS

5 DIGITS

6 DIGITS

7 DIGITS

8 DIGITS

CODED RESTORE

ENABLED/DISABLED

WEB ACCESS

ENABLED/DISABLED

Allows/restricts access to the web browser.

OPEN ZONES

ENABLED/DISABLED

ALLOW ENGINEER

ENABLED/DISABLED

ALLOW MANUFACT. *

ENABLED/DISABLED

SHOW STATE

ENABLED/DISABLED

EOL RESISTANCE

NONE
SINGLE 1K
SINGLE 1K5
SINGLE 2K2
SINGLE 4K7
SINGLE 10K
SINGLE 12K
DUAL 1K / 470R
DUAL 1K / 1K
DUAL 2K2 / 1K0
DUAL 2K2 / 1K5
DUAL 2K2 / 2K2
DUAL 2K2 / 4K7
DUAL 2K7 / 8K2
DUAL 2K2/ 10K
DUAL 3K0 / 3K0
DUAL 3K3 / 3K3
DUAL 3K9 / 8K2
DUAL 4K7 / 2K2
DUAL 4K7 / 4K7
DUAL 5K6 / 5K6
DUAL 6K8 / 4K7
DUAL 10K / 10K
MASK_1K_1K_6K8
MASK_1K_1K_2K2
MASK_4K7_4K7_2K2

SMS AUTH MODE

PIN ONLY

CALLER ID ONLY

PIN + CALLER ID

SMS PIN ONLY

SMS PIN + CALLER ID

PACE AND PIN

ENABLED/DISABLED

RESTORE ON UNSET

ENABLED/DISABLED

Note: To comply with PD6662, you must disable this option.

ENGINEER RESTORE

ENABLED/DISABLED

OFFLINE TAMPER

ENABLED/DISABLED

ENGINEER LOCK

ENABLED/DISABLED

If enabled, system cannot be reset using yellow button on controller unless an Engineer PIN is input on the keypad.

SECURE PIN

ENABLED/DISABLED

CLOCK SETTINGS

AUTOMATIC DST

MAINS TIME SYNC

SUSPICION AUDIBLE

ENABLED/DISABLED

SHOW CAMERAS

ENABLED/DISABLED

SEIS TEST ON SET

ENABLED/DISABLED

ALERT FORBID SET

ENABLED/DISABLED

ANTIMASK SET

DISABLED

TAMPER

FAULT

ALARM

ANTIMASK UNSET

DISABLED

TAMPER

FAULT

ALARM

RETRIGGER DURESS

ENABLED/DISABLED

RETRIGGER PANIC

ENABLED/DISABLED

SILENCE AUD VER.

ENABLED/DISABLED

ENGINEER EXIT

ENABLED/DISABLED

* Not available for SPC42xx, SPC43xx.