The following table shows the maximum number of users, user profiles and user devices for the panel:
Maximum No. | SPC4xxx | SPC5xxx | SPC6xxx |
---|---|---|---|
Users |
100 |
500 |
2500 |
User Profiles |
100 |
100 |
100 |
User Profiles per User |
5 |
5 |
5 |
PACE Devices |
32 |
250 |
250 |
SMS IDs |
32 |
50 |
100 |
Web Passwords |
32 |
50 |
100 |
RF Fobs |
32 |
50 |
100 |
MDT Devices |
32 |
32 |
32 |
WARNING: If upgrading from a firmware version prior to version 3.3, note the following: - The Engineer web password, if configured, is deleted and must be reentered after upgrade. - All existing users will be assigned to new user profiles corresponding to their previous user access levels. If max. number of user profiles is exceeded, no profile is assigned (see Adding/Editing User Profiles). Review all user configuration after a firmware upgrade. - The default Engineer ID is changed from 513 to 9999. |