Click one of the standard keypad identifying parameters.
Configure the fields as described in the table below.
|
Description |
Enter a unique description to identify the keypad. |
| Function Keys (in idle state) | |
|
Panic |
Select Enable, Disable or Enabled Silent. If enabled, panic alarm is activated by pressing the 2 soft keys together. |
|
Verification |
If you assign a verification zone to the keypad, when a panic alarm is triggered by pressing 2 soft keys together or by entering a duress code, audio and video events are activated. |
| Visual Indications | |
|
Backlight |
Select when keypad backlight is on. Options are: On after key is pressed; Always on; Always off. |
|
Indicators |
Enable or disable the LED’s on the keypad. |
|
Setting state |
Select if setting state should be indicated in idle mode. |
| Audible Indications | |
|
Buzzer |
Enable or disable the buzzer on the keypad. |
|
Partset Buzzer |
Enable or disable buzzer during exit time on Partset. |
|
Keypress |
Select if the speaker volume for the key presses should be activated. |
| Deactivation | |
|
Calendar |
Select if the keypad should be limited by calendar. See Calendars. |
|
Mapping gate |
Select if keypad should be limited by a mapping gate. |
|
Keyswitch |
Select if keypad should be limited by a keyswitch. |
|
PACE Entry |
Tick this box to disable the keys on the keypad during the entry time when a PACE is configured on the keypad. |
| Areas | |
|
Location |
Select the secured area where the keypad is located. |
|
Areas |
Select which areas can be controlled through keypad. |
| Options | |
|
Delay Fullset |
Select to configure a delayed set across all keypads. The location of the keypad is ignored and all areas will perform a full exit time count down. |
| NOTICE: An area should be assigned to a keypad only if the keypad is inside the assigned area, and if an entry/exit route is defined. If an area is assigned, when the particular area is set or unset then entry and exit timers are used (if configured). Other features related to entry/exit routes also become available. If no area is assigned, the area is set or unset immediately and other entry/exit features are not available. |
See also
Click one of the comfort keypad identifying parameters.
Configure the fields as described in the table below.
|
Description |
Enter a unique description to identify the keypad. |
| Function Keys (in idle state) | |
|
Panic |
Select Enable, Disable or Enabled Silent. If enabled, panic alarm is activated by pressing F1 and F2 soft keys together. |
|
Fire |
Enable to allow fire alarm to be activated by pressing F2 and F3 soft keys together. |
|
Medical |
Enable to allow medical alarm to be activated by pressing F3 and F4 soft keys together. |
|
Fullset |
Enable to allow Fullset to be activated by pressing F2 key twice. |
|
Partset A |
Enable to allow Partset A to be activated by pressing F3 key twice. |
|
Partset B |
Enable to allow Partset B to be activated by pressing F4 key twice. |
| Visual indications | |
|
Backlight |
Select when keypad backlight is on. Options are: On after key is pressed; Always on; Always off. |
|
Backlight Intensity |
Select the intensity of illumination of the backlight. Range 1–8 (High). |
|
Indicators |
Enable or disable the LED’s on the keypad. |
|
Setting state |
Enable if setting state should be indicated in idle mode. (LED) |
|
Logo |
Enable if logo should be visible in idle mode. |
|
Analog Clock |
Select position of clock if visible in idle mode. Options are Left Aligned, Center Aligned, Right Aligned or Disabled. |
|
Emergency Keys |
Enable if Panic, Fire and Medical function keys should be indicated in the LCD display. |
|
Direct Set |
Enable if Fullset/Partset function keys should be indicated in the LCD display. |
| Human Icon | Enable if Mapping Gate should be indicated. |
| Audible indications | |
|
Alarms |
Select speaker volume for alarm indications or disable sound. |
|
Entry/Exit |
Range is 0–7 (Max volume) |
|
Chime |
Select speaker volume for entry and exit indications or disable sound. |
|
Keypress |
Range is 0–7 (Max volume) |
|
Voice Annunciation |
Select speaker volume for chime or disable sound. |
|
Partset Buzzer |
Range is 0–7 (Max volume) |
| Quiet Mode |
Enable this setting to disable the buzzer during entry and exit when the keypad is in an armed area. NOTE: Keypad only audible for entry/exit/setting/unsetting if the area is the same as the keypad location, or if the keypad is performing the operation. |
| Deactivation | |
|
Calendar |
Select if the keypad should be limited by calendar. See Calendars. |
|
Mapping gate |
Select if keypad should be limited by a mapping gate. |
|
Keyswitch |
Select if keypad should be limited by a keyswitch. |
|
PACE Entry |
Tick this box to disable the keys on the keypad during the entry time when a PACE is configured on the keypad. |
| Areas | |
|
Location |
Select the secured area where the keypad is located. |
|
Areas |
Select which areas can be controlled through keypad. |
| Options | |
|
Delay Fullset |
Select to configure a delayed set across all keypads. The location of the keypad is ignored and all areas will perform a full exit time count down. |
| Keypad Access Level |
Select keypad access level (1 to 3). Level 1 – All functions Level 2 – Arm, disarm, and restore only Level 3 – View only |
| NOTICE: An area should be assigned to a keypad only if the keypad is inside the assigned area, and if an entry/exit route is defined. If an area is assigned, when the particular area is set or unset then entry and exit timers are used (if configured). Other features related to entry/exit routes also become available. If no area is assigned, the area is set or unset immediately and other entry/exit features are not available. |