Compliance with NF and A2P approvals including CYBER requirements

Address of Certifying Body

 

CNPP Cert

Pôle Européen de Sécurité - Vernon

Route de la Chapelle Réanville

CD 64 - CS 22265

F-27950 SAINT MARCEL

www.cnpp.com

AFNOR Certification

11 rue François de Pressensé

93571 Saint Denis La Plaine Cedex

www.marque-nf.com

 

To comply with NF and A2P installation regulations, this housing must be sealed by affixing the accompanying Tamper Label after installation.

Compliance with NF and A2P approvals including CYBER requirements

 

To comply with the NF & A2P and CYBER requirements, the HTTP Web server must be disabled according to the following instructions.

The system configuration can only be done with the SPC Connect Pro tool via the USB socket of the SPC control panel.

To disable the SPC panel web interface:

  1. Enter programming mode and select the Communications option.

  2. On the Services tab, uncheck the HTTP enabled box.

This will disable the SPC panel web interface.

Compliance with NF and A2P approvals including CYBER requirements - SPC Products

SPC products listed have been tested according to NF324 - H58, with reference to RTC50131-6 and RTC50131-3 and current EN certifications. See Compliance with EN50131 Approvals.

Product Type

Configuration

Standard

Logo

SPC6350.320 + SPCP355.300

(Cert. 1233700001 + Cert.8033700002)

60h, unmonitored

NF Grade 3,

Class 1

SPC5350.320 + SPCP355.300

(Cert. 1233700001 + Cert.8033700002)

60h, unmonitored

SPC6350.320

(Cert. 1233700001)

60h, unmonitored

SPC5350.320

(Cert. 1233700001)

60h, unmonitored

SPC6330.320 + SPCP333.300

(Cert. 1233700001)

60h, unmonitored

NF Grade 3,

Class 1

SPC5330.320 + SPCP333.300

(Cert. 1232200003)

60h, unmonitored

SPC6330.320

(Cert. 1233700001)

30h, monitored

SPC5330.320

(Cert. 1232200003)

30h, monitored

SPC5320.320

(Cert. 1232200003)

36h, unmonitored

NF Grade 2,

Class 1

SPC4320.320

(Cert. 1232200003)

36h, unmonitored

SPCN110.000

SPCN320.000

SPCK420.100

SPCK620.100

SPCK623.100

SPCE652.100

SPCE452.100

SPCE110.100

SPCE120.100

 

NF Grade 2 and 3,

Class 1