Changing wireless settings

To change wireless settings, select Configuration > Hardware > Wireless > Wireless Settings.

See table below for further information.

Two Way Wireless

Enable or disable two-way wireless depending on the transceiver you are using.

Enable two-way wireless if you are using SPCW120 Wireless Transceiver.

Disable two-way wireless if you are using SiWay RF Kit (SPCW110, 111, 112, 114 ).

Filter

Click to filter low strength RF signals.

Detect RF JAM

Click to activate an alert if RF interference is detected.

Wireless Lost Event

Click to send Wireless Lost event over CID/SIA and FlexC.

Supervision

Set the amount of time in minutes between occurrences of two way wireless signal supervision.

Antenna

Select the type of antenna connected to the wireless module (internal or external) from the drop down menu. The type of antenna required for the wireless module depends on the type of wireless module fitted.

Missing Supervision

Select whether a wireless sensor that is reported as missing registers a tamper condition on the signet panel.

A wireless sensor is reported as missing when no supervision signal has been received from the sensor for a period greater than the programmed Wireless Lost timer. See Timers.

RF FOB SOS

Select how the SOS buttons on the RF Fob should operate.:

  • Disable

  • Enable

  • Enabled Silent

  • User Medic

  • User Holdup

  • RF Output

WPA Test Schedule1

Enter a maximum period (in days) between WPA tests.

Prevent Setting Time

Enter a time in minutes after which, if the sensor fails to report, a setting is prevented for an area where the wireless zone is.

This setting applies to the following intrusion zones only:

  • Alarm

  • Entry/Exit

  • Exit Term

  • Panic

  • Hold up

  • Tamper

  • Lock Supervision

  • Seismic

  • All OK

  • Setting Authorisation

  • Lock Element

Device Lost Time

Enter a number of minutes after which the wireless device (sensor or WPA) device is reported as lost.

1A WPA is compatible with SiWay RF Kit (SPCW110, 111, 112, 114 ) only.

 

For CE regulatory compliance, the SPCW120 product is to be fitted to the following products only:

  • SPC5330.320-L1

  • SPC6330.320-L1

  • SPC4320.320-L1

  • SPC5320.320-L1

  • SPC5350.320-L1

  • SPC6350.320-L1