Programmable areas |
16 |
Max. number of user PINs |
500 |
Remote controls |
Up to 100 |
PACE Devices |
250 |
Wireless Panic Alarm |
Up to 128 |
Event memory |
10,000 intrusion events, 10,000 access events |
Number of on-board zones |
|
Max. number of hardwired zones |
128 |
Max. number of wireless zones |
120 (take away wired zones) |
Max. number of Intrunet wireless detectors per wireless receiver (recommended) |
20 |
EOL resistor |
Dual 4k7 (default), other resistor combinations configurable |
Relay Outputs |
|
Electronic Outputs |
|
Firmware |
V3.x |
Door capacity |
Max. 16 entry doors or 8 entry/exit doors |
Number of card reader |
Max. 16 |
Radio module |
Optional (SPCW110) |
Verification |
16 verification zones with max. 4 IP-cameras and 16 audio devices. |
Video |
Up to 16 pre/16 post event images (by JPEG resolution 320 x 240, max. 1 frame/sec.) |
Audio |
Up to 60sec. pre/60sec. post audio recording |
Field bus 1) |
X-BUS on RS-485 (307kb/s) |
Number of field devices 2) |
Max. 48 (16 keypads, 8 door-expanders, 16 input/output expanders) |
Connectable field devices |
|
Interfaces |
|
Tamper contact |
|
Power supply |
Type A (per EN50131-1) |
Mains voltage |
230V AC, + 10%/-15%, 50Hz |
Mains fuse |
|
Power consumption |
|
Operating current |
|
Quiescent current |
SPC53xx Controller: Max. 170mA at 12V DC (195mA with PSTN, 300mA with GSM, 325mA with PSTN and GSM) |
Output voltage |
13–14V DC in normal conditions (mains powered and fully charged battery), min. 10.5V DC when powered by secondary device (before system shut down to battery deep discharge protection) |
Low voltage trigger |
11V DC |
Overvoltage protection |
|
Peak to Peak ripple |
Max. 5% of output voltage |
Auxiliary power (nominal) |
|
Battery type |
Battery not supplied |
Battery charger |
|
Battery protection |
|
Software update |
Local and remote upgrade for controller, peripherals and GSM/PTSN modems. |
Calibration |
No calibration checks required (calibrated at manufacturing) |
Serviceable parts |
|
Operating temperature |
-10 to +50°C |
Relative humidity |
Max. 90% (non condensing) |
Colour |
RAL 9003 (signal white) |
Weight |
|
Dimensions (W x H x D) |
|
Housing |
|
Housing can contain up to |
|
IP/IK Rating |
30/06 |
ATS |
5 |
ATP |
15 |
Event Profiles |
10 |
Event Exceptions |
50 |
Command Profiles |
8 |
1) Max. 400m between devices/cable types IYSTY 2 x 2 x Ø 0.6mm (min.), UTP cat5 (solid core) or Belden 9829.
2) More I/O expanders can be addressed instead of a keypad or door expander, but number of programmable inputs/outputs cannot exceed specified system limits.