Programmable areas |
4 |
Max. number of user PINs |
100 |
Remote controls |
Up to 32 |
PACE Devices |
32 |
Wireless Panic Alarm |
Up to 128 |
Event memory |
1000 intrusion events, 1000 access events |
Number of on-board zones |
8 |
Max. number of hardwired zones |
32 |
Max. number of wireless zones |
32 (take away wired zones) |
Max. number of Intrunet wireless detectors per wireless receiver (recommended) |
20 |
EOL resistor |
Dual 4k7 (default), other resistor combinations configurable |
Number of on-board relays |
1 strobe (30V DC/1A resistive switching current) |
Number of on-board open coll. |
2 internal/external bell, 3 freely programmable (each max. 400mA resistive switching current, supplied via auxiliary output) |
Firmware |
V3.x |
Door capacity |
Max. 4 entry doors or 2 entry/exit doors |
Number of card reader |
Max. 4 |
Radio module |
|
Verification |
4 verification zones with max. 4 IP-cameras and 4 audio devices. |
Video |
Up to 16 pre/16 post event images (by JPEG resolution 320 x 240, max. 1 frame/sec.) |
Audio |
Up to 60sec. pre/60sec. post audio recording |
Field bus 1) |
X-BUS on RS-485 (307kb/s) |
Number of field devices 2) |
Max. 11 (4 keypads, 2 door-expanders, 5 input/output expanders) |
Connectable field devices |
|
Interfaces |
|
Tamper contact |
Front spring tamper, 2 auxiliary tamper contact inputs |
Power supply |
Type A (per EN50131-1) |
Mains voltage |
230V AC, + 10%/ -15%, 50Hz |
Mains fuse |
250mA T (replaceable part on mains terminal block) |
Power consumption |
SPC42xx: Max. 160mA at 230V AC SPC43xx: Max. 200mA at 230V AC |
Operating current |
SPC42xx Controller: Max. 160mA at 12V DC SPC43xx Controller: Max. 200mA at 12V DC |
Quiescent current |
SPC42xx Controller: SPC43xx Controller: |
Output voltage |
13–14V DC in normal conditions (mains powered and fully charged battery), min. 10.5V DC when powered by secondary device (before system shut down to battery deep discharge protection) |
Low voltage trigger |
7.5V DC |
Overvoltage protection |
15.7V DC |
Peak to Peak ripple |
Max. 5% of output voltage |
Auxiliary power (nominal) |
Max. 750mA at 12V DC |
Battery type |
SPC422x/4320: YUASA NP7-12FR (7Ah), Battery not supplied |
Battery charger |
SPC422x/4320: Max. 72h to 80% of battery capacity |
Battery protection |
Current limited to 1A (fuse protected), deep discharge protection at 10.5V DC +/- 3% |
Software update |
Local and remote upgrade for controller, peripherals and GSM/PTSN modems. |
Calibration |
No calibration checks required (calibrated at manufacturing) |
Serviceable parts |
No serviceable parts |
Operating temperature |
-10 to +50°C |
Relative humidity |
Max. 90% (non condensing) |
Colour |
RAL 9003 (signal white) |
Weight |
SPC422x/4320: 4.500kg |
Dimensions (W x H x D) |
SPC422x/4320: 264 x 357 x 81mm |
Housing |
SPC4320.320: Small metal housing (1.2mm mild steel) SPC422x.220: Small housing with metal base (1.2mm mild steel) and plastic lid |
Housing can contain up to |
SPC422x/4320: 1 additional expander (size 150 x 82mm) |
IP rating |
30 |
ATS |
3 |
ATP |
8 |
Event Profiles |
5 |
Event Exceptions |
10 |
Command Profiles |
5 |
1) Max. 400m between devices/cable types IYSTY 2 x 2 x Ø 0.6mm (min.), UTP cat5 (solid core) or Belden 9829.
2) More I/O expanders can be addressed instead of a keypad or door expander, but number of programmable inputs/outputs cannot exceed specified system limits.