Each zone type on the SPC system has an associated output type (an internal flag or indicator). When a zone type is activated, that is, a door or window opens, smoke is detected, an alarm is detected, and so on, the corresponding output is activated.
Scroll to the expander/output to be programmed and press SELECT.
If the output activations are recorded in the system event log (that is, enabled, items recorded/disabled, items) the programming options are available as shown in the table below.
|
NAMES |
Used to help identify the output; enter a specific and descriptive name. |
|
OUTPUT TYPE |
Determines the output type; see the table in Outputs types and output ports, for a description of output types. |
|
OUTPUT MODE |
Determines the style of the output: continuous, momentary or pulsed. |
|
POLARITY |
Determines whether the output is activated on a positive or negative polarity. |
|
LOG |
Determines if system log is enabled or disabled. |
| For the output test procedure, see Output Test. |