Compliance with VdS approvals
This installation document encompasses the required product installation information for VdS approvals.
Vanderbilt
SPC42xx/43xx/53xx/63xx : VdS Approval Nr. G 112104, G112124, and G112128. VdS EN Certificates EN-ST000142, EN-ST000143, EN-ST000055, EN-ST000056, EN-ST000057, EN-ST000058, EN-ST000061, EN-ST000062.
Siemens
SPC42xx/43xx/53xx/: VdS Approval Nr. G116035. VdS EN Certificates EN-ST000225, EN-ST000226, EN-ST000227, EN-ST000228, EN-ST000229, EN-ST000230, EN-ST000231, EN-ST000232.
This section describes the compliance of this system with VdS approvals.
Configuring software for VdS compliance
To set the system for VdS compliance, do the following:
-
Log on to the panel with the browser.
-
Click Full Engineer.
-
Click Configuration > System > Standards.
-
Select Europe in the Continent section of the page.
-
Select Germany in the Region Compliance section of the page.
-
Select the VDS grade required by your installation type.
Hardware Fault reporting — in Configuration > System > System Options, you must select the Enabled + Reporting (10s) option from the Watchdog Output Mode drop-down list. Hardware faults are not reported if the Engineer is logged in to the system. |
Hardware
VdS compliance requires the following:
-
A G5 housing with Front tamper implemented as a minimum requirement.
-
Keypads do not show status information if the system is armed.
-
The number of supported zones is as follows:
– 512 zones in ring configuration
– 128 zones per X-Bus in multi-drop (spur) configuration
-
The following end of line resistance combinations do not comply with VdS standards:
– 1k, 470 ohm
– 1k, 1k, 6k6 ohm