Compliance with INCERT Approvals
Software Requirements
Selecting Belgium (*) under Region implements local or national requirements which supercede EN50131 requirements.
Selecting Grade 2 or Grade 3 selects EN50131 compliance plus any additional INCERT requirements:
-
Only an engineer can restore a tamper. For INCERT, this applies across all grades.
This is normally only a requirement for Grade III En50131. -
A tamper on an Inhibited/Isolated zone must be sent to an ARC and displayed to the user.
For INCERT, tampers are processed for isolated zones. On all other standard variations, tampers are ignored on isolated zones. -
User PIN codes must be defined with more than 4 digits.
Hardware Requirements
-
The minimum battery capacity for SPC42xx/43xx/52xx/53xx/63xx is 10Ah/12V. If a 10Ah battery is used, then the battery is biased to the left of the housing and the bottom flap is bent to meet the battery.
-
Fit jumper (J12) on the battery selector for 17/10Ah battery use and remove for 7Ah battery.
-
The amount of current from Aux output using a 10Ah battery for SPC42xx/SPC52xx is:
COMMS
NONE (mA)
PSTN (mA)
GSM (mA)
PSTN+GSM (mA)
Standby time
12 h
568
543
438
413
24h
214
189
84
59
30 h
143
118
13
N/A
60h
2
N/A
N/A
N/A
-
The amount of current from Aux output using a 10Ah battery for SPC43xx/SPC53xx/ SPC63xx is:
COMMS
NONE (mA)
PSTN (mA)
GSM (mA)
PSTN+GSM (mA)
Standby time
12 h
538
513
408
383
24 h
184
159
54
29
30 h
113
88
N/A
N/A
60 h
N/A
N/A
N/A