Compliance with INCERT Approvals

Software Requirements

Selecting Belgium (*) under Region implements local or national requirements which supercede EN50131 requirements.

Selecting Grade 2 or Grade 3 selects EN50131 compliance plus any additional INCERT requirements:

  • Only an engineer can restore a tamper. For INCERT, this applies across all grades.
    This is normally only a requirement for Grade III En50131.

  • A tamper on an Inhibited/Isolated zone must be sent to an ARC and displayed to the user.
    For INCERT, tampers are processed for isolated zones. On all other standard variations, tampers are ignored on isolated zones.

  • User PIN codes must be defined with more than 4 digits.

Hardware Requirements

  • The minimum battery capacity for SPC42xx/43xx/52xx/53xx/63xx is 10Ah/12V. If a 10Ah battery is used, then the battery is biased to the left of the housing and the bottom flap is bent to meet the battery.

  • Fit jumper (J12) on the battery selector for 17/10Ah battery use and remove for 7Ah battery.

  • The amount of current from Aux output using a 10Ah battery for SPC42xx/SPC52xx is:

    COMMS

    NONE (mA)

    PSTN (mA)

    GSM (mA)

    PSTN+GSM (mA)

    Standby time

    12 h

    568

    543

    438

    413

    24h

    214

    189

    84

    59

    30 h

    143

    118

    13

    N/A

    60h

    2

    N/A

    N/A

    N/A

  • The amount of current from Aux output using a 10Ah battery for SPC43xx/SPC53xx/ SPC63xx is:

    COMMS

    NONE (mA)

    PSTN (mA)

    GSM (mA)

    PSTN+GSM (mA)

    Standby time

    12 h

    538

    513

    408

    383

    24 h

    184

    159

    54

    29

    30 h

    113

    88

    N/A

    N/A

    60 h

    N/A

    N/A

    N/A

    N/A